1. Introduction

IPX3/4 spray nozzle test equipment can meet the requirement of IEC60529 clauses 14.2.3 and 14.2.4 and figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The equipment is consisted by spray nozzle, water tank and control box. This equipment is to simulate the raining conditions to check the physical performance of outdoor luminaires, household appliance, auto parts and etc.

 

2. Features

● For IPX3 and IPX4 tests.

● The spray nozzle is processed by CNC technology, the head is made of pure brass, and the surface is mirror-polished. The moving shield is made of aluminum, and the other parts are made of SUS304 stainless steel.

● The surface of the nozzle head is sprayed with an anti-rust coating, which can effectively prevent the watermark on the surface of the nozzle from producing patina and affecting the appearance.

● The spray nozzle has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 300 pitch, 4 outer circles of 24 holes at 150pitch), completely meet the requirement of IEC60529.

● The control box includes timer, power switch button, emergency stop button, start button and flowmeter.

 

3. Specification

Outer size (L*W*H)

870mm*600mm*950mm (control box)

370mm*115mm*165mm (spray nozzle)

Spray nozzle diameter

102mm

Number of holes

121

Hole diameter

Φ0.5mm

Holes position

1 hole at center

1 inner circles of 12 holes at 300 pitch

4 outer circles of 24 holes at 150pitch

Outer diameter of water inlet

Φ16mm

Outer diameter of water pipe

Φ28mm

Flow rate

10L/min±5%

Flowmeter adjustment method

Manual adjustment  

Water pressure range

50-150Kpa

Flowmeter display

Glass flow meter

Capacity of water tank

150L

Working power

220V/50Hz

Water source

1. The user is required to configure a water source for the equipment at the installation site, with a water pressure not less than 0.2Mpa, and install a 4/8 inch faucet.

2. The faucet is not more than 2 meters away from the equipment

Requirement for the site

The ground is level, the drainage is unobstructed, the ground and walls are waterproofed, and the floor drain or drainage ditch is set

 


评论

此博客中的热门博文

How to conduct the ESD test?

  What is ESD test? Electrostatic discharge immunity test is a basic EMC test . S tandard IEC61000-4-2 provide the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects . T he standard establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. The standard IEC61000-4-2 does not intend to specify the tests to be applied to particular apparatus or system, it is to give a general basic reference to all concerned product .   S o before conduct the test, an appropriate test level should be selected according to the product's characters and its working occasion.   Contact discharge and air discharge methods The test leve...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts, the standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to ...