跳至主要内容

AC/DC Withstand Voltage and Insulation Resistance Tester

 AC/DC Withstand Voltage and Insulation Resistance Tester

1. Introduction

HY9320 withstand voltage and insulation resistance tester is a kind of electric safety test equipment, it is widely used in the fields of household appliance, transformer, electric appliance, components and etc. to check the safety performance (voltage withstand test and insulation resistance test). The tester has the features of small volume, nice appearance and simple operation. Contact us to get the formal quotation

  


2. Features

● Meet the requirements of CCC, IEC, EN, VDE, BS, UL, JIS standards.

● 4.3 inch TFT-LCD display, simple panel operation

● Voltage ramp up, ramp down function. Holding time can be set arbitrarily for insulation resistance test.

● Preset up and lower alarming value, there is an audible and visual alarm when exceeds the limit

● The DC withstand voltage test has a rapid discharge function to avoid the danger of electric shock caused by the residual voltage

● With arc detection function

● The anti-electric wall technology detects the circuit at any time to prevent electric shock damage and ensure the safety of personnel

● Overvoltage, overcurrent protection, and has current clear function. Built-in cooling fan.

● It can store 20 test files, each file can store 20 test steps, and the test modes can be combined arbitrarily.

● Support SCPI and MODBUS two protocols, which is convenient for component automation test system.


3. Parameters

Model

HY9320

Withstand voltage test

Output voltage

AC

Output range

AC:0.050-5.000KV

Waveform

Sine-wave

Distortion

<3%

Operating Frequency

50Hz/60Hz

Frequency Accuracy

±1%

Output Power

1000VA (5.000KV, 20mA)

Voltage Regulation

±(1.0%+50V)

DC

Output range

DC:0.050~6.000KV

Signal source frequency

600Hz

Output power

600VA (6.000KV, 10mA)

Voltage regulation

±(1.0%+100V)

Voltage resolution

1V

Voltage output accuracy

±(1.0% setting+5V) (no-load)

Accuracy

±(2%SV+5V)

Test current range

AC

Test range

0.001mA-20mA

Short-circuit current

>40mA (Set output voltage>500V)

Current resolution

0.001mA

Current accuracy

±(2.0% reading+5digit)

actual current

OFF 0.001mA-20mA

DC

Test range

0.1μA-20.00mA

Current accuracy

±(2.0% reading+5digit)

Discharge function

Automatic discharge after the test is over

Insulation resistance test

Output voltage

0.050KV-2.500KV

Voltage resolution

1V

Voltage accuracy

±(1.0% reading+2V)

Maximum output current

10mA

Maximum output power

25VA (2500V/10mA)

Output instantaneous short-circuit current

>20mA (set output voltage>500V)

Load regulation

≤1% (rated power)

Ripple (1KV)

≤3% (1KV, no-load)

Discharge function

Automatic discharge after the test is over

Test resistance

0.1MΩ-10GΩ

Resistance display range

10mA: 0.1MΩ-0.5MΩ

2mA: 0.5MΩ-5MΩ

200μA: 5MΩ-50MΩ

20μA: 50MΩ-500MΩ

2μA: 500MΩ-10GΩ

Resistance measurement accuracy

≥500V

1MΩ-1GΩ±(5%reading+5digit)

1GΩ-10GΩ±(10%reading+5digit)

<500V

0.1MΩ-1GΩ±(10%reading+5digit)

1GΩ-10GΩ

Current measurement accuracy

±(1.5% reading+5 digit)

Arc detection

OFF class 1-9

Current upper limit

0.001mA-20mA(AC), 0.1μA-10mA(DC)

Current lower limit

0.001mA-20mA(AC), 0.1μA-10mA(DC)

Resistance upper limit

OFF, 0.1MΩ-10GΩ

Resistance lower limit

0.1MΩ-10GΩ

discriminant output

LCD display PASS/FAIL, sound alarming

Voltage sag time

0s-999.9s

Voltage holding time

0.3s-999.9s (for DC withstand voltage test only)

Accuracy of timer

±(0.2% setting value±0.1s)

Storage and interface

20 test files, each file can have 20 test steps

USB host (support 128g max.)

Control interface

HANDLER, SINGAL

Protocol

SCPI, Modbus RTU

Communication Interface

RS232C, LAN

Accessories

Test fixture, HV probe, fuse, power cable

Working Power

220V, 50Hz/60Hz

Dimension

L283mm*D432*H108mm

Weight

13KG


 


评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...