跳至主要内容

AC/DC Withstand Voltage and Insulation Resistance Tester

 AC/DC Withstand Voltage and Insulation Resistance Tester

1. Introduction

HY9320 withstand voltage and insulation resistance tester is a kind of electric safety test equipment, it is widely used in the fields of household appliance, transformer, electric appliance, components and etc. to check the safety performance (voltage withstand test and insulation resistance test). The tester has the features of small volume, nice appearance and simple operation. Contact us to get the formal quotation

  


2. Features

● Meet the requirements of CCC, IEC, EN, VDE, BS, UL, JIS standards.

● 4.3 inch TFT-LCD display, simple panel operation

● Voltage ramp up, ramp down function. Holding time can be set arbitrarily for insulation resistance test.

● Preset up and lower alarming value, there is an audible and visual alarm when exceeds the limit

● The DC withstand voltage test has a rapid discharge function to avoid the danger of electric shock caused by the residual voltage

● With arc detection function

● The anti-electric wall technology detects the circuit at any time to prevent electric shock damage and ensure the safety of personnel

● Overvoltage, overcurrent protection, and has current clear function. Built-in cooling fan.

● It can store 20 test files, each file can store 20 test steps, and the test modes can be combined arbitrarily.

● Support SCPI and MODBUS two protocols, which is convenient for component automation test system.


3. Parameters

Model

HY9320

Withstand voltage test

Output voltage

AC

Output range

AC:0.050-5.000KV

Waveform

Sine-wave

Distortion

<3%

Operating Frequency

50Hz/60Hz

Frequency Accuracy

±1%

Output Power

1000VA (5.000KV, 20mA)

Voltage Regulation

±(1.0%+50V)

DC

Output range

DC:0.050~6.000KV

Signal source frequency

600Hz

Output power

600VA (6.000KV, 10mA)

Voltage regulation

±(1.0%+100V)

Voltage resolution

1V

Voltage output accuracy

±(1.0% setting+5V) (no-load)

Accuracy

±(2%SV+5V)

Test current range

AC

Test range

0.001mA-20mA

Short-circuit current

>40mA (Set output voltage>500V)

Current resolution

0.001mA

Current accuracy

±(2.0% reading+5digit)

actual current

OFF 0.001mA-20mA

DC

Test range

0.1μA-20.00mA

Current accuracy

±(2.0% reading+5digit)

Discharge function

Automatic discharge after the test is over

Insulation resistance test

Output voltage

0.050KV-2.500KV

Voltage resolution

1V

Voltage accuracy

±(1.0% reading+2V)

Maximum output current

10mA

Maximum output power

25VA (2500V/10mA)

Output instantaneous short-circuit current

>20mA (set output voltage>500V)

Load regulation

≤1% (rated power)

Ripple (1KV)

≤3% (1KV, no-load)

Discharge function

Automatic discharge after the test is over

Test resistance

0.1MΩ-10GΩ

Resistance display range

10mA: 0.1MΩ-0.5MΩ

2mA: 0.5MΩ-5MΩ

200μA: 5MΩ-50MΩ

20μA: 50MΩ-500MΩ

2μA: 500MΩ-10GΩ

Resistance measurement accuracy

≥500V

1MΩ-1GΩ±(5%reading+5digit)

1GΩ-10GΩ±(10%reading+5digit)

<500V

0.1MΩ-1GΩ±(10%reading+5digit)

1GΩ-10GΩ

Current measurement accuracy

±(1.5% reading+5 digit)

Arc detection

OFF class 1-9

Current upper limit

0.001mA-20mA(AC), 0.1μA-10mA(DC)

Current lower limit

0.001mA-20mA(AC), 0.1μA-10mA(DC)

Resistance upper limit

OFF, 0.1MΩ-10GΩ

Resistance lower limit

0.1MΩ-10GΩ

discriminant output

LCD display PASS/FAIL, sound alarming

Voltage sag time

0s-999.9s

Voltage holding time

0.3s-999.9s (for DC withstand voltage test only)

Accuracy of timer

±(0.2% setting value±0.1s)

Storage and interface

20 test files, each file can have 20 test steps

USB host (support 128g max.)

Control interface

HANDLER, SINGAL

Protocol

SCPI, Modbus RTU

Communication Interface

RS232C, LAN

Accessories

Test fixture, HV probe, fuse, power cable

Working Power

220V, 50Hz/60Hz

Dimension

L283mm*D432*H108mm

Weight

13KG


 


评论

此博客中的热门博文

The material of standardized cookware in EN60350-2 version 2018 and version 2013

The standardized cookwares referred in this article are designed according to EN(IEC)60350-2 table (Z)3. The diameter of the cookware bottom (outside), diameter of the lid, lid hole circle diameter, number of holes on the circle, total cookware height (outside) and flatness of cookware bottom are specified in table (Z)3. The materials of side wall, cookware bottom and lid are different. In version 2018, the side wall of cookware is made of stainless steel AISI type 304, the cookware bottom is made of stainless steel AISI type 430, and and the lid is made of aluminium. In version 2013, the side wall of cookware is made of 1.4301 stainless steel, the cookware bottom is made of stainless steel 1.4016, and the lid is made of aluminium. Items Version 2018 Version 2013 Remark material thickness material thickness Side wall   stainless steel AISI  304 1mm±0.05mm 1.4301 stainless steel 1mm±0.05mm C ylindrical without handles or protrusions. Cookware bottom stainless steel AISI  ...

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...