跳至主要内容

How to choose the IK code test apparatus?

IK coding system is to indicate the degrees of protection provided by enclosures for electrical equipment against harmful external mechanical impact, which is given by IEC62262. The code is consisted by codes letters (IK) and characteristic group numbers (00 to 10), and each characteristic group number standards for an impact value, the values as below:

IK code
IK00
IK01
IK02
IK03
IK04
IK05
IK06
IK07
IK08
IK09
IK10
Impact energy(J)
*
0.14
0.2
0.35
0.5
0.7
1
2
5
10
20

In order to give a common standard to electrotechnical equipment, IEC60068-2-75 environmental testing regarding hammer tests mentions three kinds of tool, pendulum hammer, spring hammer, and vertical hammer. To obtain repeatable and reproducible results, the test is more depends on the details of apparatus.

The choice of the test apparatus depends on the orientation of the surface to be tested and on the energy level. Not all methods can be used in every case. It is self-evident that a pendulum hammer can only be used on vertical surfaces without overhangings. Similarly the vertical hammer can normally only be used on accessible horizontal surfaces. When the specimen cannot be moved or turned, for any reason, the choice is limited. The advantage of the spring hammer is that it can be used in any position, provided there is enough room to apply it correctly, and that the specified impact energy does not exceed 2J. For higher energy levels, a spring hammer would be too difficult to handle, and could even be hazardous for the operator.

Hammer test is widely applied to electric appliance, lamp and etc. For example, according to IEC60598-1-2008 clause 4.13.1, all the LED lamps requires do the hammer impact test.

Pego tester is professional on spring hammer and pendulum hammer which meet the requirements of IEC60068-2-75 regarding Eha, Ehb and Ehc, welcome to contact for more information.  

IK01 to IK06 (0.14J to 1J) Universal Spring Hammer:
http://www.pegotester.com/IK02_to_IK06_universal_spring_hammer.html#_jcp=3_2

http://www.pegotester.com/IK07_2J_spring_hammer.html#_jcp=3_2

IK07 to IK10 (2J to 20J) Pendulum Impact Hammer:
http://www.pegotester.com/IK07_to_IK10_pendulum_impact_hammer.html#_jcp=3_2

IK07 to IK10 (2J to 20J) Vertical Impact Hammer
http://www.pegotester.com/IK07_to_IK10_vertical_impact_hammers.html#_jcp=3_2

评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...