跳至主要内容

How to position the appliance in the test corner?

For heating appliance and combined appliance:
1. Appliances normally placed on a floor or table in use, are placed on the floor and as near to the wall as possible.
2. Appliances normally fixed on a wall shall fixed on one of the walls, and as near to other wall and floor or ceiling as is likely to occur, taking into account the instructions.
3. Appliance normally fixed to a ceilling shall fixed to the ceilling, and as near to the walls as is likely to occur, taking into account in the instructions.

For motor operated appliance:
1. Appliances normally placed on a floor or table in use are placed on a horizontal support.
2. Appliances normally fixed to a wall are fixed on a vertial support.
3. Appliance normally fixed to a ceilling are fixed underneath a horizontal support.

Requirement for test corner:
The test corner, support and installation of buit-in appliances shall be made by plywood which has about 20mm thick and be coated with dull black paint. Thermocouples used for determing the temperature rise of the surface of walls, ceilling and floor of the test corner are attached to the back of small blackened disk (made by copper or brass), the blackened disk has 15mm in diameter and 1mm thick. The front of disk in flush with the surface of the board.

The test corner made by Pego is strictly designed according to IEC60335-1 chapter 11.


评论

此博客中的热门博文

The material of standardized cookware in EN60350-2 version 2018 and version 2013

The standardized cookwares referred in this article are designed according to EN(IEC)60350-2 table (Z)3. The diameter of the cookware bottom (outside), diameter of the lid, lid hole circle diameter, number of holes on the circle, total cookware height (outside) and flatness of cookware bottom are specified in table (Z)3. The materials of side wall, cookware bottom and lid are different. In version 2018, the side wall of cookware is made of stainless steel AISI type 304, the cookware bottom is made of stainless steel AISI type 430, and and the lid is made of aluminium. In version 2013, the side wall of cookware is made of 1.4301 stainless steel, the cookware bottom is made of stainless steel 1.4016, and the lid is made of aluminium. Items Version 2018 Version 2013 Remark material thickness material thickness Side wall   stainless steel AISI  304 1mm±0.05mm 1.4301 stainless steel 1mm±0.05mm C ylindrical without handles or protrusions. Cookware bottom stainless steel AISI  ...

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...