跳至主要内容

What is draught-proof enclosure?

The draught-proof enclosure is rectangular, with a double skin on top and on at leat three sides and with a solid base, the double skins are of perforated metal, space approximately 150mm apart, with regular perforations of 1mm to 2mm diameter, occupying about 40% of whole area of each skin. It is applied to thermal test of luminaire under the conditions of normal operation and abnormal operation. 

The inernal surface are painted with a matt paint. The three principal internal dimensions are each at least 900mm. There shall be a clearance of at least 200mm between the internal surfaces and any part of the largest luminaire for which the enclosure is designed (If it is required to test two or more luminaires in a large enclosure, be attention to take that radiation from one luminaie can not affect any other).

There is a clearance of at least 300mm above the top of the enclosure and around the perforated sides. The enclosure is at a location protected as far as possible from draughts and sudden changes in air temperature; it is also protected from sources of radiant heat.

A luminaire for direct fixing to a ceiling or wall shoulb be fixed to a mounting surface comprising a wood or wood-fiber board. A non-combustible insulating material is used if the luminaire not suitable for mounting on a combustible surface. The board is 15mm to 20mm thick, and extends no less than 100mm (but preferably not more than 200mm) beyond the normal projection of the smoothed outline of the luminaire. There is a clearance of at least 100mm between the board and the internal surfaces of the enclosure. The board is painted black with a matt non-metalic paint.

A lumianire for coner-fixing is fixed in a corner comprising two boards, each complying with the preceding requirements.

A third-board is required if the luminaire is to be fixed in a vertical corner immediately below a simulated ceiling.

Pego designed the draught-proof enclosure according to IEC60598-1 annex D, the size can be customized according to the customers requirement, for more details, please check the specification at.

http://www.pegotester.com/draught_proof_enclosure.html#nSL=%5B5%2C6%2C7%2C8%5D&skeyword=draught&_pp=0_35



评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...