跳至主要内容

What is draught-proof enclosure?

The draught-proof enclosure is rectangular, with a double skin on top and on at leat three sides and with a solid base, the double skins are of perforated metal, space approximately 150mm apart, with regular perforations of 1mm to 2mm diameter, occupying about 40% of whole area of each skin. It is applied to thermal test of luminaire under the conditions of normal operation and abnormal operation. 

The inernal surface are painted with a matt paint. The three principal internal dimensions are each at least 900mm. There shall be a clearance of at least 200mm between the internal surfaces and any part of the largest luminaire for which the enclosure is designed (If it is required to test two or more luminaires in a large enclosure, be attention to take that radiation from one luminaie can not affect any other).

There is a clearance of at least 300mm above the top of the enclosure and around the perforated sides. The enclosure is at a location protected as far as possible from draughts and sudden changes in air temperature; it is also protected from sources of radiant heat.

A luminaire for direct fixing to a ceiling or wall shoulb be fixed to a mounting surface comprising a wood or wood-fiber board. A non-combustible insulating material is used if the luminaire not suitable for mounting on a combustible surface. The board is 15mm to 20mm thick, and extends no less than 100mm (but preferably not more than 200mm) beyond the normal projection of the smoothed outline of the luminaire. There is a clearance of at least 100mm between the board and the internal surfaces of the enclosure. The board is painted black with a matt non-metalic paint.

A lumianire for coner-fixing is fixed in a corner comprising two boards, each complying with the preceding requirements.

A third-board is required if the luminaire is to be fixed in a vertical corner immediately below a simulated ceiling.

Pego designed the draught-proof enclosure according to IEC60598-1 annex D, the size can be customized according to the customers requirement, for more details, please check the specification at.

http://www.pegotester.com/draught_proof_enclosure.html#nSL=%5B5%2C6%2C7%2C8%5D&skeyword=draught&_pp=0_35



评论

此博客中的热门博文

How to conduct the ESD test?

  What is ESD test? Electrostatic discharge immunity test is a basic EMC test . S tandard IEC61000-4-2 provide the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects . T he standard establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. The standard IEC61000-4-2 does not intend to specify the tests to be applied to particular apparatus or system, it is to give a general basic reference to all concerned product .   S o before conduct the test, an appropriate test level should be selected according to the product's characters and its working occasion.   Contact discharge and air discharge methods The test leve...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts, the standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to ...