IP code system is given by IEC60529, which indicates the degrees of protection provided by an enclosure against access to hazardous parts, ingress of solid foreign objects, ingress of water and to give additional information in connection with such protection. IP code system is consisted by code letters(IP, international protection), first characteristic numeral ( 0 to 6 or letter X, indicates protection degrees against access to hazardous parts and solid foreign objects), second characteristics numeral (0 to 8 or letter X, indicates protection degrees against ingress of water), additional letters (A to D, optional) and supplement letters(H,M,S,W). Generally, the additional letters and supplement letters can be omitted, the first and second numerals can be replaced by X if without the characteristic. 

The first characteristic numeral implies two meanings: 
1. Enclosure provides protection of persons against access to hazardous parts by preventing or limiting the ingress of a part of human body or an object held by a person. 
Numeral 0 (IP0X) means non protected. Numeral 1 means with the back of a hand, verified by Probe A; Numeral 2 (IP2X) means with a finger, verified by probe B; Numeral 3(IP3X)means with a tool, verified by probe C; Numeral 4 to 6 (IP4X, IP5X, IP6X) means with a wire, which can verified with probe D.

2. Enclosure provides protection of equipment against the ingress of solid foreign object.
Numeral 0 (IP0X) means non protected. Numeral 2 (IP2X) means with Φ50mm sphere, verified by probe 1; Numeral 3 (IP3X) means with Φ12.5mm sphere, verified by probe 2; Numeral 3 (IP3X) means with Φ2.5mm sphere, verified by probe C; Numeral 4 (IP4X) means with Φ1.0mm probe, verified by probe D. Numeral 5 (IP5X) means dust-protected, ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety. Numeral 6 (IP6X) means dust-tight, no ingress of dust. Both IP5X and IP6X can be verified with dust chamber.

According to IEC60529 clause 13.4, the dust chamber for IP5X and IP6X testing request talcum powder during the dust test, and the talcum powder used shall be able to pass through a square-meshed sieve the nominal wire diameter of which is 50μm and the nominal width of a gap between wires 75 μm. The amount of talcum powder to be used is 2kg per cubic meter of the test chamber volume. The talcum powder shall not have been used for more than 20 tests. JY-SC series dust-proof test chamber is completely meet the requirements. For more details, please contact: sales@pegotester.com.

 

评论

此博客中的热门博文

How to conduct the ESD test?

  What is ESD test? Electrostatic discharge immunity test is a basic EMC test . S tandard IEC61000-4-2 provide the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects . T he standard establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. The standard IEC61000-4-2 does not intend to specify the tests to be applied to particular apparatus or system, it is to give a general basic reference to all concerned product .   S o before conduct the test, an appropriate test level should be selected according to the product's characters and its working occasion.   Contact discharge and air discharge methods The test leve...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts, the standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to ...