ISO 17025 and CNAS

ISO17025 is the international standard for laboratory accreditation services; the latest version is released in May, 2005. The full name of ISO/IEC17025:2005-5-15 is Accreditation Criteria for the Competence of Testing and Calibration Laboratories. ISO17025 standard is the laboratory management standard formulated by the international Standardization Organization ISO/CASCO (Conformity Assessment Committee). Internationally the organization that manages laboratory accreditation is International Laboratory Accreditation Cooperation (ILAC), attended by 44 laboratory accreditation institute including CHINA NATIONAL ACCREDITATION COMMITTEE FOR LABORATORIES (CNACL).

ISO17025 standard mainly includes: definitions, organization and management, quality system, audits and reviews, personnel, accommodation and environmental conditions, equipment and reference materials, traceability and calibration, calibration and test methods, sample management, record, certificate and report, subcontracting tests and calibrations, purchasing services and suppliers, complaints etc. This standard core content is equipment and reference materials, traceability and calibration, calibration and test methods and sample management; these contact emphasis is to assess whether the laboratory or test capability meets the expected requirements.

CHINA NATIONAL ACCREDITATION SERVICE FOR CONFORMITY ASSESSMENT (CNAS) laboratory accreditation criteria are according to ISO/IEC17025, it is an internationally accepted standard for laboratory quality and technical requirements. The laboratory gets accredited by CNAS, which means that it has been established a set of quality management system based on international standards. As long as the personnel carry out work according to the system strictly, the laboratory’s technical capacity will be guaranteed. The test/calibration services provided by the laboratory to the customer can claim to be accordance with the international standards.

CNAS is the only laboratory accreditation institute in China; it bears nationwide laboratories for ISO17025 standard approval. All calibration and test laboratories can adopt and implement the ISO17025 standard. In accordance with international practice, data provided by the ISO17025 standard laboratory have legal effect and get international recognized. At present, China has more than 1,000 laboratories that get through the ISO17025 standard certification. Through the implementation of standard to improve the accuracy of the test data and results and expand the laboratory’s reputation, thereby greatly improve the economic and social benefits.

All Pego’s products can be sent to the lab authorized by CNAS and get the calibration certificate, which meets ISO17025 standard. 

评论

此博客中的热门博文

The material of standardized cookware in EN60350-2 version 2018 and version 2013

The standardized cookwares referred in this article are designed according to EN(IEC)60350-2 table (Z)3. The diameter of the cookware bottom (outside), diameter of the lid, lid hole circle diameter, number of holes on the circle, total cookware height (outside) and flatness of cookware bottom are specified in table (Z)3. The materials of side wall, cookware bottom and lid are different. In version 2018, the side wall of cookware is made of stainless steel AISI type 304, the cookware bottom is made of stainless steel AISI type 430, and and the lid is made of aluminium. In version 2013, the side wall of cookware is made of 1.4301 stainless steel, the cookware bottom is made of stainless steel 1.4016, and the lid is made of aluminium. Items Version 2018 Version 2013 Remark material thickness material thickness Side wall   stainless steel AISI  304 1mm±0.05mm 1.4301 stainless steel 1mm±0.05mm C ylindrical without handles or protrusions. Cookware bottom stainless steel AISI  ...

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...