UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

 1. Introduction:

The high current arc ignition test apparatus is designed according to IEC60950-1:2001 clause 4.7.3.6, BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc.. Its used to measure and assess solid insulating material against to resistance to ignition from arcing electrical sources.

A power 240V(AC)/60Hz is to be supplied to the test electrodes (fixed electrode and movable electrode), a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0.5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±25mm/s, the test is to be continued until ignition of the sample occurs, a hole is burned through the sample, or until a total of 200 cycles has elapsed. The high-current ignition performance level is to be assigned base on the mean number of arcs to caused ignition.

2. Parameters:

Control mode

PLC

Station

1 station

Electrodes

1). Material: copper (fixed electrode), stainless steel (movable electrode )

2). Size: 3.2mm in diameter, 152mm overall length and 300 chisel (fixed electrode), 3.2mm in diameter, 152mm overall length, 600 conical (movable electrode)

Electrode included angle

45° to the horizontal

Test voltage

240V

Arc ignition current

32.5A±5%A (adjustable)

Arc ignition power factor

COSφ0.5±0 (adjustable)

Arc ignition speed

254mm/s±25mm/s

Arc ignition frequency

40 arcs/min (adjustable)

Arc times

200 times (1~9999 times, digital display, presettable)

Sample size

127mm*12.7mm*(2~12)mm

Power supply

220V/50Hz, 10kVA







评论

此博客中的热门博文

How to conduct the ESD test?

  What is ESD test? Electrostatic discharge immunity test is a basic EMC test . S tandard IEC61000-4-2 provide the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects . T he standard establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. The standard IEC61000-4-2 does not intend to specify the tests to be applied to particular apparatus or system, it is to give a general basic reference to all concerned product .   S o before conduct the test, an appropriate test level should be selected according to the product's characters and its working occasion.   Contact discharge and air discharge methods The test leve...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts, the standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to ...