 CMA

CMA is short for China Metrology Accredidation. It is a mark of qualified measurement certification by a testing organization, and the organization with this mark is an inspection agency that is legal in China and authorized by the national or provincial measurement certification management department.

Institutions engaged in social-oriented testing and inspection of products in China must be reviewed by the national, provincial, and municipal metrological certification management agencies in conjunction with the review agency, and they can only engage in testing and inspection activities after they are established or authorized by law. Therefore, CMA is mandatory.

 

ILAC-MRA


ILAC-MRA is short for ILAC Mutual Recognition Arrangement. It is an international mutual recognition mark. The purpose of ILAC is to improve the acceptance of testing and calibration results issued by accredited laboratories in order to eliminate technical trade barriers and promote the establishment of international cooperation in international trade. Till to 12/12/2008, 62 laboratory accreditation bodies in 48 economies in the world have signed the ILAC mutual recognition agreement. The identification certificates with this mark can be mutually recognized internationally, and the identification results can be recognized by the United States, Japan, France, Germany, the United Kingdom and other countries.


CNAS

CNAS is short for China National Accrediation Board of Laboratories. CNAS is the symbol of national laboratory. The presence of this mark indicates that the inspection agency has passed the assessment of the China National Laboratory Certification Committee, and its inspection capabilities have reached the level of a national laboratory. According to the relevant agreements of China's accession to the WTO, the CNAS logo can be mutually recognized internationally, for example, it can be recognized by countries such as the United States, Japan, France, Germany, and the United Kingdom.


All the equipment of Pego can come with a calibration certificate issued by the labs recognized by CNAS and ILAC-MRA. 

www.pegotester.com


评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...