The difference of the dielectric strength test instrument on standards IEC60065 and UL1310

 
https://www.pegotester.com/dielectric_strength_test_instrument.html#_jcp=3_17

The dielectric strength test instrument is an auxiliary equipment for testing the dielectric strength of insulating material. The two standards IEC60065:2014 and UL1310:2017 have referred this equipment, but have difference on the details. In standard IEC60065:2014, there are detailed drawings as below, but there are no specific regulations on the material of the electrode, in the standard UL1310:2017, the size and material of the electrode are described in detail, but no drawings are given.


In IEC60065:2014:


In UL1310:2017: 


 But in practice, we usually make two standard requirements into one device, the equipment will includes 2 electrodes, the electrode has diameter 5mm±0.1mm and weight of 100g±1g is conform to IEC60065 standard, and the other electrode has diameter 6.4mm±0.1mm and weight of 50g±1g is conform to UL1310 standard. The electrodes are normally made of stainless steel. In UL1310, it mentions that the electrode also can made of brass, but compared with stainless steel, the brass will oxidize after long-term use and cause poor contact.

 

Below is the difference between the standards IEC60065 and UL1310, and also it is the parameters of dielectric strength test instrument made by PEGO, please contact the sales to get the formal quotation.

Standards

IEC60065

UL1310

Mass of the moveable electrode

100g±1g

50g±1g

Diameter of metal pin

Φ5mm±0.1mm

Φ6.4mm±0.1mm

Diameter of support pin

Φ5mm±0.1mm

Φ6.4mm±0.1mm

edges rounded radius

0.5mm

0.8mm

Material of metal pin and support pin

Stainless steel/brass


评论

此博客中的热门博文

The material of standardized cookware in EN60350-2 version 2018 and version 2013

The standardized cookwares referred in this article are designed according to EN(IEC)60350-2 table (Z)3. The diameter of the cookware bottom (outside), diameter of the lid, lid hole circle diameter, number of holes on the circle, total cookware height (outside) and flatness of cookware bottom are specified in table (Z)3. The materials of side wall, cookware bottom and lid are different. In version 2018, the side wall of cookware is made of stainless steel AISI type 304, the cookware bottom is made of stainless steel AISI type 430, and and the lid is made of aluminium. In version 2013, the side wall of cookware is made of 1.4301 stainless steel, the cookware bottom is made of stainless steel 1.4016, and the lid is made of aluminium. Items Version 2018 Version 2013 Remark material thickness material thickness Side wall   stainless steel AISI  304 1mm±0.05mm 1.4301 stainless steel 1mm±0.05mm C ylindrical without handles or protrusions. Cookware bottom stainless steel AISI  ...

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...