跳至主要内容

The difference of the dielectric strength test instrument on standards IEC60065 and UL1310

 
https://www.pegotester.com/dielectric_strength_test_instrument.html#_jcp=3_17

The dielectric strength test instrument is an auxiliary equipment for testing the dielectric strength of insulating material. The two standards IEC60065:2014 and UL1310:2017 have referred this equipment, but have difference on the details. In standard IEC60065:2014, there are detailed drawings as below, but there are no specific regulations on the material of the electrode, in the standard UL1310:2017, the size and material of the electrode are described in detail, but no drawings are given.


In IEC60065:2014:


In UL1310:2017: 


 But in practice, we usually make two standard requirements into one device, the equipment will includes 2 electrodes, the electrode has diameter 5mm±0.1mm and weight of 100g±1g is conform to IEC60065 standard, and the other electrode has diameter 6.4mm±0.1mm and weight of 50g±1g is conform to UL1310 standard. The electrodes are normally made of stainless steel. In UL1310, it mentions that the electrode also can made of brass, but compared with stainless steel, the brass will oxidize after long-term use and cause poor contact.

 

Below is the difference between the standards IEC60065 and UL1310, and also it is the parameters of dielectric strength test instrument made by PEGO, please contact the sales to get the formal quotation.

Standards

IEC60065

UL1310

Mass of the moveable electrode

100g±1g

50g±1g

Diameter of metal pin

Φ5mm±0.1mm

Φ6.4mm±0.1mm

Diameter of support pin

Φ5mm±0.1mm

Φ6.4mm±0.1mm

edges rounded radius

0.5mm

0.8mm

Material of metal pin and support pin

Stainless steel/brass


评论

此博客中的热门博文

How to conduct the ESD test?

  What is ESD test? Electrostatic discharge immunity test is a basic EMC test . S tandard IEC61000-4-2 provide the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects . T he standard establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. The standard IEC61000-4-2 does not intend to specify the tests to be applied to particular apparatus or system, it is to give a general basic reference to all concerned product .   S o before conduct the test, an appropriate test level should be selected according to the product's characters and its working occasion.   Contact discharge and air discharge methods The test leve...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts, the standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to ...