跳至主要内容

IPX8 High Pressure Transparent Water Tank

1. Introduction

IPX8 High Pressure Transparent Water Tank can meet the requirement of IEC60529 for IPX8 testing and IEC60598. The pressure in the jar can be precisely automatically controlled in purpose of checking the tightness and the leak points (by observe the bubbling during the test).The equipment is mainly consisted by transparent Sealed jar and control unit.

 


2.  Features

 For IPX8 test.

 Working principle: The sample is placed into the water, close the lid and setup the test pressure and pressure holding time, then start the equipment. When the sample is in water, increase the air pressure on the water surface to the set value and then maintain the pressure. If there is a leak in the sample, the water will be pressed into the sample, and the air in the sample will be discharged, and the leakage point of the sample can be observed through bubbles. After the test is completed, the pressure can be automatically stopped, and the air inside the jar can be automatically drained. The operator can open the lid and take out the test sample.

 The jar is made of acrylic, it is full transparent for observe purpose.

 Adopts special silicone sealing ring which has good elasticity and not easy to damage.

 The jar has passed the pressure test by applying 2 times the working pressure, and equip with branded safety valve to protection the user.

 Control unit: controlled by digital pressure gauge and time relay, the pressure in the jar and pressure holding time can be setup. One-key start to complete the test automatically.

 Pressure control: pressure sensor made by Panasonic, can auto control the test pressure. Control accuracy: ±0002Mpa, display accuracy: 0.001Mpa.

 

3. Parameter

Outer size

500mm*550mm*600mm (L*W*H)

Inner size

Φ270mm*300mm

Wall thickness

15mm

Jar Material

acrylic

Flange thickness

20mm

Flange material

Stainless steel

Weight

40KG

Pressure control mode

auto

Pressure error

±0.002 Mpa

Sensor display accuracy

0.001Mpa

Test water depth

0-30m

Pressure adjustment range

0.01MPa-0.3MPa

Safety valve exhaust pressure

0.35MPa

Pressure hold time

0-999min

Protection device

Leakage switch protection, mechanical safety valve protection

Working Power

AC220V/50Hz (single phase), 100W

Working condition

Temperature: 5℃~35℃

Relative humidity: ≤85%

Pressure: 86kPa~106kPa

Test water

Tap water or pure water

Air source

The air compressor is provided by the user, and the recommended output air pressure: 0.6Mpa—0.8Mpa. Install the female quick connector

评论

此博客中的热门博文

How to conduct the ESD test?

  What is ESD test? Electrostatic discharge immunity test is a basic EMC test . S tandard IEC61000-4-2 provide the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects . T he standard establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. The standard IEC61000-4-2 does not intend to specify the tests to be applied to particular apparatus or system, it is to give a general basic reference to all concerned product .   S o before conduct the test, an appropriate test level should be selected according to the product's characters and its working occasion.   Contact discharge and air discharge methods The test leve...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts, the standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to ...