跳至主要内容

GB/T 1002-2021 Single Phase 2-Pole Plug and Socket-Outlet Test Gauges

 GB1002 Single-Phase Plug and Socket-Outlet Gauges

1. Introduction

The single phase plug and socket-outlet test Gauges are designed according to GB1002-2021 figures 8/9/10/11/12/13/14/15/16. They are applicable to verify the single phase plugs and fixed or mobile socket-outlets for household with an AC frequency of 50 Hz, rated voltage of 250 V, rated current not exceeding 16A.

Standard/figure number

Gauge name

Qty

Test Purpose

GB/T 1002-2021, Figure 8

Single Phase Two-Pole Plug Gauge (≤10A)

1

The pins of the plug shall be able to pass the gauges shown in Figures 8 and 9. If the plug pin is provided with an insulating sheath, the insulating sheath part does not need to pass the gauge in Figure 8 and Figure 9.

The plugs can smoothly plug-in and pull out in vertical and horizontal directions with a small force shows qualified, Otherwise, the distance between the pins or the inclination and position of the pins do not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 9

Single Phase Two-Pole with Earth Plug Gauge (10A, 16A)

2

GB/T 1002-2021, Figure 10

Go Gauge for Single Phase Two-Pole socket-Outlet (10A)

1

The Go Gauges shall be able to insert into the jacks of the socket-outlet.

The Go Gauges can smoothly insert into the jacks of the socket-outlet in verticall directions with a small force shows qualitified. Otherwise, the spacing, inclination, position, jacks of the socket-outlet do not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 11

Go Gauge for single Phase Two-Pole Socket-Outlet with Earthing (10A, 16A)

2

GB/T 1002-2021, Figure 12

Not Go Gauge for Single Pin of Single Phase Socket-Outlet (10A, 16A)

2

The Not Go Gauge shall be not able to insert into the jacks of the socket-outlet.  

The Not Go Gauge can not smoothly insert into the jacks of the socket-outlet in vertical direction with a small force shows qualitified. Otherwise, the size of jacks of the socket-outlet do not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 13

Non-Contact Gauge for Single Phase Two-Pole Socket-Outlet (10A)

1

Th Non-Contact Gauges shall not be able to contact the live kits of socket-outlet.

The non-contact gauges can smoothly insert into the jacks of the socket-outlet in vertical and horizontal directions with a small force, but cannot contact the copper sets (female terminal) shows qualified, Otherwise, the sizes of the socket-outlet does not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 14

Non-Contact Gauge for Single Phase Two-Pole Socket-Outlet with Earthing (10A, 16A)

2

GB/T 1002-2021, Figure 15

Contact Gauge for Single Phase

Two-Poles Socket-Outlet (10A)

1

The contact gauge shall be able to contact the live kits of socket-outlet.

The contact gauges can smoothly insert into the jacks of the socket-outlet in vertical and horizontal directions with a small force and  contact the copper sets (female terminal) shows qualified, Otherwise, the sizes of the socket-outlet does not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 16

Contact Gauge for Single Phase Two-Poles Socket-Outlet with Earthing 10A,16A)

2

    




评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...