跳至主要内容

GB/T 1002-2021 Single Phase 2-Pole Plug and Socket-Outlet Test Gauges

 GB1002 Single-Phase Plug and Socket-Outlet Gauges

1. Introduction

The single phase plug and socket-outlet test Gauges are designed according to GB1002-2021 figures 8/9/10/11/12/13/14/15/16. They are applicable to verify the single phase plugs and fixed or mobile socket-outlets for household with an AC frequency of 50 Hz, rated voltage of 250 V, rated current not exceeding 16A.

Standard/figure number

Gauge name

Qty

Test Purpose

GB/T 1002-2021, Figure 8

Single Phase Two-Pole Plug Gauge (≤10A)

1

The pins of the plug shall be able to pass the gauges shown in Figures 8 and 9. If the plug pin is provided with an insulating sheath, the insulating sheath part does not need to pass the gauge in Figure 8 and Figure 9.

The plugs can smoothly plug-in and pull out in vertical and horizontal directions with a small force shows qualified, Otherwise, the distance between the pins or the inclination and position of the pins do not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 9

Single Phase Two-Pole with Earth Plug Gauge (10A, 16A)

2

GB/T 1002-2021, Figure 10

Go Gauge for Single Phase Two-Pole socket-Outlet (10A)

1

The Go Gauges shall be able to insert into the jacks of the socket-outlet.

The Go Gauges can smoothly insert into the jacks of the socket-outlet in verticall directions with a small force shows qualitified. Otherwise, the spacing, inclination, position, jacks of the socket-outlet do not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 11

Go Gauge for single Phase Two-Pole Socket-Outlet with Earthing (10A, 16A)

2

GB/T 1002-2021, Figure 12

Not Go Gauge for Single Pin of Single Phase Socket-Outlet (10A, 16A)

2

The Not Go Gauge shall be not able to insert into the jacks of the socket-outlet.  

The Not Go Gauge can not smoothly insert into the jacks of the socket-outlet in vertical direction with a small force shows qualitified. Otherwise, the size of jacks of the socket-outlet do not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 13

Non-Contact Gauge for Single Phase Two-Pole Socket-Outlet (10A)

1

Th Non-Contact Gauges shall not be able to contact the live kits of socket-outlet.

The non-contact gauges can smoothly insert into the jacks of the socket-outlet in vertical and horizontal directions with a small force, but cannot contact the copper sets (female terminal) shows qualified, Otherwise, the sizes of the socket-outlet does not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 14

Non-Contact Gauge for Single Phase Two-Pole Socket-Outlet with Earthing (10A, 16A)

2

GB/T 1002-2021, Figure 15

Contact Gauge for Single Phase

Two-Poles Socket-Outlet (10A)

1

The contact gauge shall be able to contact the live kits of socket-outlet.

The contact gauges can smoothly insert into the jacks of the socket-outlet in vertical and horizontal directions with a small force and  contact the copper sets (female terminal) shows qualified, Otherwise, the sizes of the socket-outlet does not match.

Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1.

GB/T 1002-2021, Figure 16

Contact Gauge for Single Phase Two-Poles Socket-Outlet with Earthing 10A,16A)

2

    




评论

此博客中的热门博文

The material of standardized cookware in EN60350-2 version 2018 and version 2013

The standardized cookwares referred in this article are designed according to EN(IEC)60350-2 table (Z)3. The diameter of the cookware bottom (outside), diameter of the lid, lid hole circle diameter, number of holes on the circle, total cookware height (outside) and flatness of cookware bottom are specified in table (Z)3. The materials of side wall, cookware bottom and lid are different. In version 2018, the side wall of cookware is made of stainless steel AISI type 304, the cookware bottom is made of stainless steel AISI type 430, and and the lid is made of aluminium. In version 2013, the side wall of cookware is made of 1.4301 stainless steel, the cookware bottom is made of stainless steel 1.4016, and the lid is made of aluminium. Items Version 2018 Version 2013 Remark material thickness material thickness Side wall   stainless steel AISI  304 1mm±0.05mm 1.4301 stainless steel 1mm±0.05mm C ylindrical without handles or protrusions. Cookware bottom stainless steel AISI  ...

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...