GB1003 3-Phases Plug and Socket-Outlet Gauges
1. Introduction
The 3-phase plug and socket-outlet test Gauges are designed according to GB1003-2016 figure 5, figure 6, figure 7, figure 8 and figure 9. They are applicable to verify the three-phase plugs and three-phase fixed or mobile socket-outlets for household with an AC frequency of 50 Hz, rated voltage of 440 V, rated current not exceeding 32 A.
2. Parameter
No. | Standard/figure number | Gauge name | Qty | Test Purpose |
1 | GB/T1003-2016, figure 5 | 3-Phases 5-Wires Plug Gauges (16A, 25A, 32A) | 3 | The plug should be able to insert into the gauge
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
2 | GB/T1003-2016, figure 6 | 3-Phases 5-Wires Socket-Outlet Go Gauges (16A, 25A, 32A) | 3 | The go gauge shall be able to insert into the jacks of the 3-phases and 5 wires socket-outlets. For 3-phases 4-wires socket-outlet, the go gauge that removes the neutral pole shown figure 6 is applied.
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
3 | GB/T1003-2016, figure 7 | 3-Phases 5-Wires Socket-Outlet Not Go Gauges (16A, 25A, 32A) | 3 | The not go gauge shall not be able to insert into the jacks of the 3-phases and 5 wires socket-outlets. For 3-phases 4-wires socket-outlet, the not go gauge that removes the neutral pole shown figure 7 is applied.
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
4 | GB/T1003-2016, figure 8 | 3-Phases 5-Wires Socket-Outlet Non Contact Gauge (16A, 25A, 32A) | 3 | The non-contact gauge shall not be able to contact the live kits of socket-outlet; For 3-phases 4-wires socket-outlet, the non-contact gauge that removes the neutral pole shown figure 8 is applied.
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |
5 | GB/T1003-2016, figure 9 | 3-Phases Socket-Outlet with Live Sleeve Contact Gauge (16A, 25A, 32A) | 3 | The contact gauge shall be able to contact the live kits corresponding to the three-phase socket-outlet
Note: The insertion force should not be greater than the maximum withdrawal force specified in GB/T2099.1. |