What is the difference between withstand voltage test and leakage current test?

 In the safety inspection items, the current test item include withstand voltage test and leakage current test, and both tests are for the current of the insulating part. But in the actual test, there are many cases where both the withstand voltage test and the leakage current test need to be carried out. Why? And what is the difference between a withstand voltage test and a leakage current test?

 

Difference 1: voltage applied to the test is different.

The difference between the withstand voltage test and the leakage current test is mainly in the voltage applied to the EUT. The voltage applied in the withstand voltage test is much higher than the rated voltage, the test is between the live & neutral wire and the electrical enclosure, it mainly tests the insulation performance of the electrical appliance. The leakage current test is to apply a 1.06 times of rated voltage to EUT, and check if there is a leakage current between live wire and ground wire. Both of which are important items for electrical appliance quality inspection, are required to be tested by the national standard to ensure consumer safety.  

 

Difference 2: The test purpose is different

The withstand voltage test is to check whether the product can withstand a certain strength of overvoltage, if the product can pass the withstand voltage test, it indicates that product has a strong ability to withstand voltage fluctuations during use, and it is not easy to cause problems such as self-damage. The leakage current test is to check if the current passing through the insulating part of the product (under normal working conditions) is lower than the safe current that human body can bear, if the product is qualified, it indicates that the product will not cause electrical damage to the human body during normal use.

 


评论

此博客中的热门博文

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...