跳至主要内容

IEC60112 Tracking Index Test Apparatus for PTI and CTI Testing

 https://www.pegotester.com/IEC60112_tracking_index_tester.html#_jcp=3_17

1. Introduction

The tracking index test apparatus is designed according to IEC60112, UL746A, GB.T4207, GB4706.1 and TMD 3628-92. On the surface of the solid insulating material, a certain voltage is applied between the platinum electrodes (2 mm × 5 mm) , and drops the pollution liquid (0.1% NH4CL) with specified droplet volume in fixed height (35mm) for 30s to evaluate the resistance of the surface of solid insulating materials under the combined action of electric field and contaminated medium, and its Comparative tracking index (CTI) and proof tracking index (PTI) are determined. Tracking index test apparatus is mainly used in the industries of lighting appliance, low voltage appliance, household appliance, motor, electronic appliance, instrument and etc. It is a good tool for research department, production department and QC department.

The tracking index test apparatus is controlled by single chip and push buttons. The test apparatus is built-in air exhaust, the front panel is transparent for easy observation of the experimental process.

 

Proof Tracking Index (PTI): the voltage value of the material subjected to 50 drops of electrolyte without electrical tracking, the unit is volt.

Comparative Tracking Index (CTI): The highest voltage value at which the surface of the material can withstand 50 drops of electrolyte without forming electrical tracking, the unit is volt.

Test solutions: The preparation ratio is 1:1000, that is 0.1g of NH4CI with 100g (100ml) of distilled water

 

2. Parameter:

Electrode material

platinum (Pt)  purity 99.8%

Electrode size

2mm±0.1mm)×(5mm±0.1mm)×(40mm±5mm), length≥12mm, Angle of chisel-edged: 30°±2°

Electrode distance

4.0mm±0.01mm, angle: 60°±5°

Electrode pressure

1.00±0.05N

Electrode distance

4.0mm ± 0.01mm

Angle

60°±5

Electrode voltage

100~600V

Height of the drops

35mm±5mm adjustable

Size of drops

20 drops:  0.380g~0.480g, 50 drops: 0.997g~1.147g

Interval of the drops

30s±0.1s, 50 drops: 24.5min±2min

Test solutions resistance

Solution A: 0.1%NH4Cl3.95±0.05Ωm, solution B: 1.7±0.05Ωm

Number of drops

0~9999 (presettable, record and display)

Test wind speed

0.2m/s

Short circuit current drop

1.0A±0.1A drop 8%

Leakage indicator

0.50A±10% , 2.00s±10%

Thermal radiation baffle

Automatic masking

Safe operation interface

automatically power off upon open the glass window

Standard

IEC60112, UL746A, ASTM D 3638-92, DIN 53480

Working studio

0.5m3 ( customizable 0.1m3, 0.5m3 or 0.75m3 according to different standard), exhaust hole: Φ100mm

Outer dimension

600mm (W)*500mm (D)*1000mm (H)

Working Power

220V/50-60Hz, 0.6KVA

 

评论

此博客中的热门博文

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...