跳至主要内容

IEC60335-1 scratch tester


Abrasion Resistance Tester/Scratch Tester

1. Introduction

Abrasion resistance tester is designed according to IEC60950 clause 2.10.8.4 and IEC60335-1 clause 21.2. It is applied to do scratch test for accessible parts of solid insulation of household appliance and printed circuit boards, to ensure the material has sufficient strength to prevent penetration by sharp implements.

 

The scratch resistance test uses a hardened steel pin for scratching. The end of the steel pin should be tapered with a apex angle of 40°. The tip should be rounded with radius of 0.25 mm ± 0.02 mm.

When performing the scratch test, the test pin is held at 80-85° to the horizontal, and scratches were performed at a speed of 20 mm/s ± 5 mm/s in a plane perpendicular to the edge of the conductor. The steel pin should be properly loaded so that the hardened steel pin can apply a force of 10N ± 0.5N along its axial direction. The scratch interval should be at least 5mm and at least 5mm away from the edge of the sample.

 

This equipment adopts the control system of PLC+ touch screen, and the performance is stable. Rotating the work surface makes it easy to realize the scratch test in both directions.

 

2. Specification

Scratching speed

0~25mm/s (adjustable)

Test times

0~9999 times (adjustable)

Scratching spacing

0~50mm (adjustable)

Working table

900 rotation

Scratch angle

80-850 (the pin is fixed by clamp)

Force applied

10N±0.5N  (option: 30N±0.5N equip with 20N weights)

Scratching pin

Rounded with a radius of 0.25 mm ± 0.02 mm

Pin Tip

40°Conical sharp

Material of the pin

Hardened steel

Working power

220V/50Hz

Control system

PLC+touch screen

Drive mode

Stepping motor

评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...