跳至主要内容

The figure numbers of the gauges in different version of UL498

 The gauges mentioned in UL498 has a bit difference on the figure numbers in different version, below is a comparison table for reference.

Name

UL498-2001

UL498-2012

UL498-2019

Articulate probe with web stop

Figure 9.1

Figure 9.1

Figure 9.1

Probe

Figure 10.1

Figure 10.1

Figure 10.1

Flat probe

Figure 31.1

Figure 31.1

Figure 31.1

Reference plug

Figure 69.1

Figure 73.1

Figure 74.1

Improper insertion test bland

Figure 94.1

Figure 98.1

Figure 100.1

Test gauge

Figure 105.1

Figure 109.1

Figure 111.1

Test blade

Figure 105.2

Figure 109.2

Figure 111.2

Receptacle test fixture

Figure 118.1

Figure 122.1

Figure 124.1

Pushout tool

Figure 118.3

Figure 122.3

Figure 124.3

Bridge

Figure 118.5

Figure 122.5

Figure 124.5

Test pin A

Figure 119.1

Figure 123.1

Figure 125.1

Test Pin B

Figure 119.2

Figure 123.2

Figure 125.2

57g ground pin

Figure 119.3

Figure 123.3

Figure 125.3

113g ground pin

Figure 119.4

Figure 123.4

Figure 125.4

NO.14 AWG test pin

Figure 129.2

Figure 133.2

Figure 136.2

Small Test probe

Figure132.1

Figure 136.1

Figure 139.1

Large test probe

 

Figure 136.2

Figure 139.2

Fixture for assembly securty test

Figure 144.2

Figure 165.2

Figure 174.2


https://www.pegotester.com/UL498_plug_test_gauges.html#_pp=0_393_21


评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...