跳至主要内容

Washing Machine Door Endurance Test Machine

https://www.pegotester.com/endurance_tester_for_washing_machine.html#_jcp=3_17

Washing Machine Door Endurance Test Machine

 1. Introduction

Washing machine door endurance test machine can meet the requirement of IEC60335-2-7 clauses 18.101 and 22.104, IEC60335-2-11 clause 20.101 and IEC60335-2-4 clause 18, it is a special test equipment applied to life test of lid or door interlock of various washing machines and tensile force test when the interlock device acts to lock the door. The washing machine door endurance test machine can be set flexibly as per different washing machine. The test machine adopts PLC controller and touch screen, and the motor drives the transmission rod to reciprocate the switch movement. It can independently realize the reciprocating action of "opening and closing" the lid and door of washing machine. The rack is made by high grade aluminium alloy, and the door is fixed by a vacuum suction cup structure, which is easy to operate and easy to control.


2. Test principle:

Use the edited program to control the power-on and power-off of the interlocking device, drive the mechanical arm through the motor, and drive the door or lid that is sucked by the vacuum suction cup to reciprocate opening and closing at a certain speed, so as to verify the reliability of the interlocking device. A force sensor is installed on the mechanical arm, which forms a closed-loop control with the servo motor, and can precisely control the closing force value. 


2. Parameter

Test stations

2, can independent test the drum washing machine and pulsator washing machine

Control system

PLC+7 inch touch screen

Drive mode

Servo motor

Sample clamping mode

vacuum suction cup, drive by pneumatic (user prepare the air compressor 0.5-0.7Mpa)

Speed of opening

0-3600/s (1.5m/s) presettable

Opening angle

0-1300 presettable

Test cycles

0-999999 presettable

Opening and closing force

0-200N presettable (The opening force is only for the tension test when the interlock device acts to lock the door)

Supply mains

0-250V adjustable

Test sample and its limitation

Electric tumble dryer, electric washing machine (includes drum washing machine with single-phase voltage250V, others 480V)

Centrifugal Dehydrator (load capacity 10KG, roller linear speed50m/s, single phase voltage250V, others 480V)

Equipment structure

a. Consisted by electrical control cabinet (built-in Load voltage regulator), test racks equip with mechanical arm

b. the drum washing machine and pulsator washing machine can be placed in 2 independent test racks, the test can be performed independently.

c. Dimension: L2500mm*W1300mm*H1300mm

d. Weight: 180kg

Working condition

a. power supply: AC220V±10%/50Hz, 6KW

b. Working conditions: 5-40 (A.T.), 20-80% R.H., 80-106kpa

Protection device

Leakage protection, over-load protection, short-circuit protection

  




评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

The material of standardized cookware in EN60350-2 version 2018 and version 2013

The standardized cookwares referred in this article are designed according to EN(IEC)60350-2 table (Z)3. The diameter of the cookware bottom (outside), diameter of the lid, lid hole circle diameter, number of holes on the circle, total cookware height (outside) and flatness of cookware bottom are specified in table (Z)3. The materials of side wall, cookware bottom and lid are different. In version 2018, the side wall of cookware is made of stainless steel AISI type 304, the cookware bottom is made of stainless steel AISI type 430, and and the lid is made of aluminium. In version 2013, the side wall of cookware is made of 1.4301 stainless steel, the cookware bottom is made of stainless steel 1.4016, and the lid is made of aluminium. Items Version 2018 Version 2013 Remark material thickness material thickness Side wall   stainless steel AISI  304 1mm±0.05mm 1.4301 stainless steel 1mm±0.05mm C ylindrical without handles or protrusions. Cookware bottom stainless steel AISI  ...