The black test corner is designed according to IEC60335-1 chapter 11 “heating”. It is applied to provide a standard required conditions for temperature rising test of electric appliance.The Black Test Corner is used for the measurement of the temperature radiated by different equipment during the tests from heating and abnormal operation. One is designed and made with the intention of determining the fulfillment of different standards as far as the registry from temperatures during the operation of the apparatus under test.

The Black Test Corner is conformed by a trihedral or tetrahedron one of black painting plywood, with a matrix of holes each 100 mm that allow to adapt thermocouples of measurement easily, specially designed for such case.

The dimension of the test corner can be customized as per the specimen, the test corner is consisted by two side plates, one bottom and one top plate (top plate is selectable), the top plate can be removed or fixed, bottom plate mounted on a structure with wheels, to allow his movement. Thermocouples of measurement is of type K ( Ø0.3mm), mounted on terminal block, so that user can connect with a temperature logger to track the temperature rising of each points; and in thermcouples end of measurement they have a copper disc of Ø15 mm and 1 mm of thickness.The amount of thermocouples is according to the necessity of the client.  The thermocouples arrangement is start from the inner corner, and the temperature measurement points spacing are arranged in the pattern of L100mm*W100mm. 


So, the customer should clarify follow issues when make enquiry

1. What size of test corner should be applied to test? 

2. How many temperature measuring points (thermocouples) will be needed? 

3. How to arrange the temperature measuring points? 

4. The multiplex temperature logger should be purchased separately. 


The following are several layout drawings for reference: 





评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...