The black test corner is designed according to IEC60335-1 chapter 11 “heating”. It is applied to provide a standard required conditions for temperature rising test of electric appliance.The Black Test Corner is used for the measurement of the temperature radiated by different equipment during the tests from heating and abnormal operation. One is designed and made with the intention of determining the fulfillment of different standards as far as the registry from temperatures during the operation of the apparatus under test.

The Black Test Corner is conformed by a trihedral or tetrahedron one of black painting plywood, with a matrix of holes each 100 mm that allow to adapt thermocouples of measurement easily, specially designed for such case.

The dimension of the test corner can be customized as per the specimen, the test corner is consisted by two side plates, one bottom and one top plate (top plate is selectable), the top plate can be removed or fixed, bottom plate mounted on a structure with wheels, to allow his movement. Thermocouples of measurement is of type K ( Ø0.3mm), mounted on terminal block, so that user can connect with a temperature logger to track the temperature rising of each points; and in thermcouples end of measurement they have a copper disc of Ø15 mm and 1 mm of thickness.The amount of thermocouples is according to the necessity of the client.  The thermocouples arrangement is start from the inner corner, and the temperature measurement points spacing are arranged in the pattern of L100mm*W100mm. 


So, the customer should clarify follow issues when make enquiry

1. What size of test corner should be applied to test? 

2. How many temperature measuring points (thermocouples) will be needed? 

3. How to arrange the temperature measuring points? 

4. The multiplex temperature logger should be purchased separately. 


The following are several layout drawings for reference: 





评论

此博客中的热门博文

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...