跳至主要内容

The water use for IP waterproof test

 As per the standard IEC60529, the waterproof test should be conducted with fresh water; in practice, we will suggest to use pure water as test water, but according to the actual situation of customers, tap water is used the most. So what effect will be worked to the specimen with different water?

1. Effect on the sample

Some high-tech electronic products will conduct electrical measurements after the waterproof test is completed, so non-conductive water like distilled water or deionized water is used as the test water.

2. Effect on the waterproof test equipment

1). when use the tap water to conduct the test, there is a filter inside the device to filter the tap water, but there will still be impurities. If the water flow rate is too low, it will cause the needle to be blocked, which will affect the test result. So if use the tap water as test water, The water in the tank should be changed every 3 days, and check the filter regularly, once the filter turns to black, it must be replaced in time.

2). When use the corrosive water as test water, although it may be required by the test, the corrosive water will pollute and corrosive the waterway, nozzles, water tank and other accessories, so as to cause the leakage.

 

In summary, it is recommended that users use pure water as test water to reduce the probability of needle clogging and prolong the service life of the waterproof testing machine.





评论

此博客中的热门博文

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts. The standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to t...