跳至主要内容

The Best Gift from Our Greek Customer

We exported the IK testing equipment to Greece in the early of 2023, and received the best gift in the end of 2023. After more than half a year of use and verification, customers have given high praise to our products, they said”the equipment works very well, thank you for the good quality equipment”, receiving such good feedback in the new year is the best gift for us, we are very grateful to our customers for their support in the past year, and we will also give back to our new and regular customers with the best quality and service in the new year.

 

The IK testing equipment includes pendulum hammer test apparatus, spring hammer test apparatus, and vertical hammer test apparatus according to IEC60068-2-75, the IK test is a mechanical impact test, includes 11 levels: IK01 (0.14J), IK02 (0.2J), IK03 (0.35J), IK04 (0.5J), IK05 (0.7J), IK06(1J), IK07 (2J), IK08 (5J), IK09 (10J), IK10 (20J), IK11 (50J).

---The spring hammer test apparatus and pendulum hammer test apparatus are recommended to perform the low energies impact tests from IK01 to IK06. The spring hammer is flexible to be used at any positions; and the low energies pendulum hammer test apparatus can be used in some specific products, like plugs, socket-outlets, mounting box, glands, cover,switches and other electrical accessories, the test samples must be fixed with mounting fixture during the test.

---The vertical hammer test apparatus and pendulum hammer test apparatus are suggested to perform the high energies impact tests from IK07 to IK11. The vertical hammer test apparatus is used to the occasions that the impact points are on the accessible horizontal surfaces of the enclosure; the high energy pendulum hammer test apparatus is used to the occasions that the impact points are on the vertical surface of the enclosure. Usually high energy impact tests are used in the industries of outdoor lightings, charging equipment and etc..

 

Pego can provide the best IK test solutions as per the customer’s requirements, please send enquiry to sales@pegotester.com. 

 


评论

此博客中的热门博文

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts, the standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to ...

The difference of the dielectric strength test instrument on standards IEC60065 and UL1310

  https://www.pegotester.com/dielectric_strength_test_instrument.html#_jcp=3_17 The dielectric strength test instrument is an auxiliary equipment for testing the dielectric strength of insulating material. The two standards IEC60065:2014 and UL1310:2017 have referred this equipment, but have difference on the details. In standard IEC60065:2014, there are detailed drawings as below, but there are no specific regulations on the material of the electrode, in the standard UL1310:2017, the size and material of the electrode are described in detail, but no drawings are given. In IEC60065:2014: In UL1310:2017:   But in practice, we usually make two standard requirements into one device, the equipment will includes 2 electrodes, the electrode has diameter 5mm±0.1mm and weight of 100g±1g is conform to IEC60065 standard, and the other electrode has diameter 6.4mm±0.1mm and weight of 50g±1g is conform to UL1310 standard. The electrodes are normally made of stainless steel...

How to conduct the ESD test?

  What is ESD test? Electrostatic discharge immunity test is a basic EMC test . S tandard IEC61000-4-2 provide the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects . T he standard establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. The standard IEC61000-4-2 does not intend to specify the tests to be applied to particular apparatus or system, it is to give a general basic reference to all concerned product .   S o before conduct the test, an appropriate test level should be selected according to the product's characters and its working occasion.   Contact discharge and air discharge methods The test leve...