跳至主要内容

scratch tester

Abrasion Resistance Tester/Scratch Tester

1. Introduction

Abrasion resistance tester is designed according to IEC60950 clause 2.10.8.4 and IEC60335-1 clause 21.2. It is applied to do scratch test for accessible parts of solid insulation of household appliance and printed circuit boards, to ensure the material has sufficient strength to prevent penetration by sharp implements.

 

The scratch resistance test uses a hardened steel pin for scratching. The end of the steel pin should be tapered with a apex angle of 40°. The tip should be rounded with radius of 0.25 mm ± 0.02 mm.

When performing the scratch test, the test pin is held at 80-85° to the horizontal, and scratches were performed at a speed of 20 mm/s ± 5 mm/s in a plane perpendicular to the edge of the conductor. The steel pin should be properly loaded so that the hardened steel pin can apply a force of 10N ± 0.5N along its axial direction. The scratch interval should be at least 5mm and at least 5mm away from the edge of the sample.

 

This equipment adopts the control system of PLC+ touch screen, and the performance is stable. Rotating the work surface makes it easy to realize the scratch test in both directions.

 https://pegotesters.com/product/scratch-tester

评论

此博客中的热门博文

The material of standardized cookware in EN60350-2 version 2018 and version 2013

The standardized cookwares referred in this article are designed according to EN(IEC)60350-2 table (Z)3. The diameter of the cookware bottom (outside), diameter of the lid, lid hole circle diameter, number of holes on the circle, total cookware height (outside) and flatness of cookware bottom are specified in table (Z)3. The materials of side wall, cookware bottom and lid are different. In version 2018, the side wall of cookware is made of stainless steel AISI type 304, the cookware bottom is made of stainless steel AISI type 430, and and the lid is made of aluminium. In version 2013, the side wall of cookware is made of 1.4301 stainless steel, the cookware bottom is made of stainless steel 1.4016, and the lid is made of aluminium. Items Version 2018 Version 2013 Remark material thickness material thickness Side wall   stainless steel AISI  304 1mm±0.05mm 1.4301 stainless steel 1mm±0.05mm C ylindrical without handles or protrusions. Cookware bottom stainless steel AISI  ...

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...