Introduction:
IPX1-2 Drip Box is designed according to IEC60529 clause 14.2.1 and 14.2.2. It is applied to simulate the conditions of vertically dripping and dripping with 15 degrees tilted, and then to check if the products ( electronics, luminaire, electric components, auto parts and etc.) can meet the requirements. The equipment can be customized according to size of test specimen .

Features:
1. For IPX1 and IPX2 testing
2. Adopts column structure, which can be fixed on floor and runs stability. Easy to pack and install.
3. The shell and turntable are made by SUS304 stainless steel, to ensure the rustless for long time use.
4. Equip with flowmeter, can accurately manual adjust the flowmeter.
5. The cone-sharp nozzles are made by brass, and easy to change. The stainless steel protective cover under the nozzles can protect user from any hurts.
6. Equip with high accuracy filter, the filter element can change regularly.
7. The drip board can lift, and will auto stop at the position of 200mm upper of the test specimen.
8. Control system: 7 inch touch screen+ Panosonic PLC.
Model
IPX12B-800
IPX12B-1000
Drip board size (mm)
800*800
1000*1000
Outer size (mm)
1000*1000*2300 (L*W*H)
1200*1200*2300 (L*W*H)
Diameter of turntable
Φ500mm
Φ600mm
Aperture of nozzle
Φ0.4mm
Grid pattern
20*20mm
Delivery rate
1~5mm/min (±0.5mm/min)
Adjust mode
Manual adjustment
Lifting height of drip board
1000~1800mm (adjustable)
Bearing
50KG
Rotation speed of turntable
1r/min
Tilt angle of turntable
00 or 150 in 4 positions
Lifting height of turntable
fixed
Test time
0~999min
Protection device
Electric leakage, hydropenia, short circuit
Working power
220V, 50Hz/60Hz, 1KW

评论

此博客中的热门博文

The material of standardized cookware in EN60350-2 version 2018 and version 2013

The standardized cookwares referred in this article are designed according to EN(IEC)60350-2 table (Z)3. The diameter of the cookware bottom (outside), diameter of the lid, lid hole circle diameter, number of holes on the circle, total cookware height (outside) and flatness of cookware bottom are specified in table (Z)3. The materials of side wall, cookware bottom and lid are different. In version 2018, the side wall of cookware is made of stainless steel AISI type 304, the cookware bottom is made of stainless steel AISI type 430, and and the lid is made of aluminium. In version 2013, the side wall of cookware is made of 1.4301 stainless steel, the cookware bottom is made of stainless steel 1.4016, and the lid is made of aluminium. Items Version 2018 Version 2013 Remark material thickness material thickness Side wall   stainless steel AISI  304 1mm±0.05mm 1.4301 stainless steel 1mm±0.05mm C ylindrical without handles or protrusions. Cookware bottom stainless steel AISI  ...

vertical impact hammers

The vertical impact hammer is designed according to IEC60068-2-75 test Ehc, the hammer consists by a striking element which falls freely from rest through a vertical height on to the specimen surface held in a horizontal plane, and the fall of the striking element shall be along a guideway, the guideway shall not rest on the specimen and the striking element shall be free of the guideway on the striking the specimen , the mass of striking element is equal to equivalent mass . 2J striking element equip with Φ 40 mm*4 71 mm guideway, 5J striking element equip with Φ6 8 mm*3 85 mm guideway, 10J striking element equip with Φ8 9 mm* 337 mm guideway, 20J striking element equip with Φ10 8 mm* 520 mm guideway, 50J striking element equip with  Φ12 9 mm* 650 mm guideway. 

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...