Introduction:
IPX1-2 Drip Box is designed according to IEC60529 clause 14.2.1 and 14.2.2. It is applied to simulate the conditions of vertically dripping and dripping with 15 degrees tilted, and then to check if the products ( electronics, luminaire, electric components, auto parts and etc.) can meet the requirements. The equipment can be customized according to size of test specimen .

Features:
1. For IPX1 and IPX2 testing
2. Adopts column structure, which can be fixed on floor and runs stability. Easy to pack and install.
3. The shell and turntable are made by SUS304 stainless steel, to ensure the rustless for long time use.
4. Equip with flowmeter, can accurately manual adjust the flowmeter.
5. The cone-sharp nozzles are made by brass, and easy to change. The stainless steel protective cover under the nozzles can protect user from any hurts.
6. Equip with high accuracy filter, the filter element can change regularly.
7. The drip board can lift, and will auto stop at the position of 200mm upper of the test specimen.
8. Control system: 7 inch touch screen+ Panosonic PLC.
Model
IPX12B-800
IPX12B-1000
Drip board size (mm)
800*800
1000*1000
Outer size (mm)
1000*1000*2300 (L*W*H)
1200*1200*2300 (L*W*H)
Diameter of turntable
Φ500mm
Φ600mm
Aperture of nozzle
Φ0.4mm
Grid pattern
20*20mm
Delivery rate
1~5mm/min (±0.5mm/min)
Adjust mode
Manual adjustment
Lifting height of drip board
1000~1800mm (adjustable)
Bearing
50KG
Rotation speed of turntable
1r/min
Tilt angle of turntable
00 or 150 in 4 positions
Lifting height of turntable
fixed
Test time
0~999min
Protection device
Electric leakage, hydropenia, short circuit
Working power
220V, 50Hz/60Hz, 1KW

评论

此博客中的热门博文

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h  

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5

UL746A High Current ARC Ignition Test Apparatus 32.5A/COSφ0.5   1.  Introduction: The high current arc ignition tes t apparatus is designed according to  IEC60950-1:2001  clause 4.7.3.6 , BS/EN60950-1:2001, BS7002:2001, GB4943-2001 and UL746A, IEC60947.1:1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-1998 and etc..  It ’ s used to measure and assess  solid insulating material against to resistance to ignition from arcing electrical sources. A power 240V(AC)/60Hz is to be supplied to the test electrodes  (fixed electrode and movable electrode) , a series (inductive-resistive) air core impedance is to be provided to yield a short circuit current of 32.5A and a power factor of 0. 5. The sample is be to positioned with the electrodes making initial contact on the surface of the sample, the circuit is to be energized and the cyclic arcing started. The timing of arcs is to be adjusted to a rate of 40 arcs/min, the rate of electrode separation is to be 254±...

what equipment can be used for IPX3 and IPX4 water ingress protection test?

1. Spray nozzle 1.  Introduction The spray nozzle hand-held device is designed according to IEC60529 figure 5, it is it is apply to verify the protection against spraying water (IPX3) and splashing water (IPX4) for large size sample. The hand-held device is consisted by spray nozzle, moving shield, counterweight, hose and pressure gauge. The spray nozzle is made of brass and has 121 holes with diameter 0.5mm (1 hole at center, 1 inner circles of 12 holes at 30 0  pitch, 4 outer circles of 24 holes at 15 0 pitch). The moving shield is made of aluminum, the counterbalanced shield is in place for IPX3 test, the water pressure is adjusted to give the specified delivery rate, the pressure to achieve this delivery rate will be in the range of 50kPa to 150kPa, and it should be kept constant during the test, the test duration is 1min/m 2  of the calculated surface of the enclosure and with a minimum duration of 5 min. For IPX4 test, the counterbalanced shield is removed fro...