跳至主要内容

IPX8 high pressure test tank




Introduction:
IPX8 continuous immersion tank is designed according to IEC60529-2001 regarding the second characteristic numerals 8. Waterproof test simulates the condition of raining, which is mainly applied to electronic products, luminaire, electric components, motor and house-holding appliance. The waterproof test can help to judge the products’ performance, and provide the basis for design, improve and inspect. IP8X test is subject to the agreement between user and manufacturer, the test simulates the condition under 0 to 50m below the water.

Features:
1). For IPX8 Testing
2). Made by #304 stainless steel, adopts integrated welding molding technology.
3). Special silicon sealing ring, with features of good elasticity and no easy to damage.
4). Equip with safety valve, will auto depressurize if exceed the rated pressure to protect the user from any hurt caused by improper operation.
5). Adopts branded electronic components, like LG, PANASONIC and OMRON.
6). Test time: 0~999 min (preset), auto depressurize when time up.
7). Pressure sensor with accuracy of 0.001Mpa (display) and ±0.002Mpa (control)
8) Four wheels with brake, easy to move.
9) Holes can be designed according to user’s demands for live test. 
Function parameter
Model
IPX8-30M-100L
Water depth test range
0~30m
Pressure adjust range
0~0.3MPa
Pressure control method
Pressure senor auto adjust
Pressure accuracy
0.001MPa
Safety valve discharge pressure
0.35Mpa
Time setting
0~999min
Protection device
Leakage protection, circuit short protection, safety valve overpressure protection
Structure Parameter
Outer size
600*780*1300mm (L*W*H)
Inner size
Φ500*500mm
Material of body
SUS304#
Flange thickness
20mm
Wight
About 60Kg
Electrical parameter
Working power
220V/50Hz
Power comsuption
100W

评论

此博客中的热门博文

How to conduct the ESD test?

  What is ESD test? Electrostatic discharge immunity test is a basic EMC test . S tandard IEC61000-4-2 provide the immunity requirements and test methods for electrical and electronic equipment subjected to static electricity discharges, from operators directly, and to adjacent objects . T he standard establish a common and reproducible basis for evaluating the performance of electrical and electronic equipment when subjected to electrostatic discharges. Electrostatic discharge is a transfer of electric charge between bodies of different electrostatic potential in proximity or through direct contact. The standard IEC61000-4-2 does not intend to specify the tests to be applied to particular apparatus or system, it is to give a general basic reference to all concerned product .   S o before conduct the test, an appropriate test level should be selected according to the product's characters and its working occasion.   Contact discharge and air discharge methods The test leve...

The relationship between standards IEC62262 and IEC60068-2-75

  The IK code is a coding system to indicate the degree of protection provided by an enclosure against harmful external mechanical impacts, the standard IEC62262 defines the impact energy corresponding to different IK codes. In general, the degree of protection applies to the complete enclosure. If parts of the enclosure have differing degrees of protection, the latter shall be indicated separately. IK00 IK01 IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10 IK11 0 0.14J 0.2J 0.35J 0.5J 0.7J 1J 2J 5J 10J 20J 50J IK00 - no protection IK01 - withstands 0.14J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 56mm on the surface) IK02 - Withstand 0.2J impact force (equivalent to the impact of an object weighing 0.25KG falling from a height of 80mm on the surface) IK03 - Withstand 0.35J impact force (equivalent to the impact of an object weighing 0.2KG falling from a height of 140mm on the surface) IK04 - Withstand 0.5J impact force (equivalent to ...

JIS D0203 rain nozzle and spray nozzle test chamber

https://www.pegotester.com/JISD0203_rain_and_spray_test_chamber.html The spray nozzle and rain nozzle test chamber is designed to meet the test requirements of JISD0203 R1/R2 rain test and S1/S2 spray test. The rain nozzle has 2 holes and spray nozzle has 40 holes. Type Symbol Test Purpose Test Method Rain Test R1 Auto parts against water direct contact water pressure: 0.01Mpa, water flow: 1.9L/min, water temperature: ordinary temperature, test time: 10min R2 Auto parts against rain or spray water   indirect contact water pressure: 0.03Mpa, water flow: 3.2L/min, water temperature: ordinary temperature, test time: 10min Spray Test S1 Auto parts against rain or jet water direct contact water pressure: 0.10Mpa, water flow: 24.5L/min, water temperature: ordinary temperature, test time: 30min S2 Auto parts against riptide water pressure: 0.30Mpa, water flow: 39.2L/min, water temperature: ordinary temperature, test time: 1h